INDUSTRY PARTNERS FOR HEATING APPLICATIONS

Custom Industrial Heating Solutions & Temperature Measurement Systems

ThermSys develops and manufactures custom heating and temperature measurement solutions for industrial applications.

Our systems are based on mineral-insulated sheathed heating cables as well as mineral-insulated signal and temperature cables. We support projects from the technical design phase through thermodynamic analysis to serial production.

Engineering partner for globally active
DAX and NASDAQ-listed companies.

THERMSYS TECHNOLOGY

Development and Manufacturing Using Mineral-Insulated Cables

Development and manufacturing based on mineral-insulated technology.
Mineral-insulated cables enable compact designs, high temperature resistance, and reproducible performance data even under demanding environmental conditions. ThermSys manufactures MI cables in-house and integrates them into custom heating and temperature measurement solutions.

Areas of expertise:

Heating Applications

Custom Heating Elements for Industrial Applications

ThermSys specializes in custom heating elements that are precisely tailored to the installation space, temperature profile, power density, and environmental conditions.

PRODUCT GROUPS

Mineral-insulated components for industrial heating and temperature measurement

Technical Applications

Industrial Heating Under Defined Boundary Conditions

At ThermSys, thermal systems are designed based on boundary conditions rather than industry-specific requirements. The temperature range, vacuum level, power density, and material requirements determine the design.

Heating in a Vacuum and Ultra-High Vacuum

Designed for low, high, and ultra-high vacuum.
Material selection, surface quality, and assembly methods are tailored to vacuum technology requirements.

High-temperature applications up to 1000 °C

Design of mineral-insulated heating systems for high surface and process temperatures, taking heat transfer and power density into account.

Compact designs with a minimum bend radius

Diameters starting at 0.5 mm allow for integration into confined installation spaces.
Bending radii starting at 2 × the outer diameter ensure design flexibility.

Integration of Temperature Measurement and Multi-Zone Control

Direct integration of sheathed thermocouples or resistance thermometers into heating plates, radiant heaters, or piping systems.

Resistance to aggressive
media, pressure, and radiation

Adaptation of the sheath material and design to withstand chemical, mechanical, and thermal stresses.

Industries for which ThermSys develops solutions

Industrial Heating Solutions for Specialized Applications

ThermSys develops custom industrial heating solutions and temperature measurement systems for applications with clearly defined technical requirements. The focus is not on standard solutions typical of a particular industry, but rather on the specific thermal challenge: the temperature range, vacuum level, power density, material requirements, and installation conditions determine the design.

Our mineral-insulated technology enables robust, reproducible, and adaptable solutions for a wide variety of industrial environments—from high-purity vacuum processes to systems subject to mechanical stress.

Branchen fur thermsys Losungen schafft

We work for internationally active industrial companies in the following sectors:

ThermSys GmbH

Your Technical Partner for Industrial Heating

ThermSys was founded in 2008 and specializes in custom industrial heating and temperature measurement applications based on mineral-insulated cables.

Mineral-insulated cables are manufactured at our own cable plant in Germany. This allows us to precisely tailor the diameter, sheath materials, and electrical characteristics to the specific application.

Experienced engineers develop solutions that take heat transfer, power density, and material behavior into account—from the concept phase through to mass production.

We are more than just a supplier. We are your development partner for industrial heating.

Thermsys GmbH

Expertise and development since 2008

In-house MI cable manufacturing in Germany

Engineering and Expertise in Thermodynamics

Partner to Global Industrial Companies

Quality and Processes

Industrial heating solutions that deliver consistent results

Reproducible industrial heating solutions through structured quality assurance. ThermSys operates under a certified quality management system in accordance with ISO 9001. All development and manufacturing processes are documented and structured in a traceable manner.

Every assembly is thoroughly tested before shipment. The tests include helium leak tests, high-voltage tests, and X-ray inspections, among others.

The traceability of materials and components is ensured. This results in industrial heating and temperature measurement systems with defined and reproducible properties.

Qualitat und Prozesse
Project Phases at a Glance

Here's How We Bring Your Industrial Heating Project to Life

Order & ERP Entry

5%

Technical & Commercial Review

15%

Binding Order Confirmation

20%

Thermodynamic Design

40%

CAD Design & Engineering

50%

Precision Manufacturing in Kahl am Main

90%

Rigorous Quality Assurance (QA)

95%

Professional Delivery

100%

Together, we'll create your ideal heating solution

Simply send us your technical requirements. We’ll take a close look at the design and materials and give you an honest assessment of feasibility—quickly and easily.

Gemeinsam realisieren wir Ihre ideale Heizlosung
FAQ

Frequently Asked Technical Questions About Mineral-Insulated Heating and Measurement Systems

If you have any further questions, please feel free to contact us at any time.

What temperatures can be achieved with mineral-insulated sheathed heating cables?

Depending on the jacket material, mineral-insulated jacketed heating cables are designed for temperatures up to 1,000 °C. Stainless steel jackets (e.g., AISI 304, 316L, or 321) are typically used up to 600 °C, while Inconel® 600 (2.4816) is used up to 1000 °C. The maximum permissible temperature depends on the material, power density, and installation conditions.

Yes, mineral-insulated heating solutions can be designed for low, high, and ultra-high vacuum. Through the appropriate selection of materials, vacuum-compatible assembly methods, and optimized surfaces and feedthroughs, applications in UHV systems can be implemented, such as in vacuum chambers or coating systems.

Mineral-insulated sheath heating wires are available in diameters ranging from 0.5 mm to 6.5 mm.
Sheathed thermocouples can be manufactured starting at a diameter of 0.25 mm.
The small diameters allow for tight bend radii starting at 2× the outer diameter and enable integration into compact assemblies.

Temperature measurement is achieved through the direct integration of sheathed thermocouples or sheathed resistance thermometers into the heating application.
Sensors can be embedded in heating plates, radiant heaters, or heated pipe systems. This enables precise temperature control and multi-zone control within the system.

Mineral-insulated sheath heating conductors allow for power densities of up to 12 W/cm² when exposed to air. The maximum permissible power density depends on the sheath material, heat dissipation, installation conditions, and temperature control. At higher power densities, a thermodynamic design is required to ensure uniform heat distribution and safe operating conditions.

True cold ends are electrically conductive connection areas with no heating effect and no increase in diameter. They are used for thermally decoupled power delivery and reduce heat input into connection and contact areas. This simplifies integration into assemblies and improves operational reliability.

Mineral-insulated heating cables are characterized by high temperature resistance, compact diameters, and tight bend radii. Compared to conventional heating elements, they allow for flexible integration into complex designs and can be used in vacuum, high-temperature, and mechanically stressed applications. The metal sheath also ensures mechanical stability and electrical safety.